  condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com model output rating pwr out 1000 watts power factor corrected single output, hot swap the 1000-watt tcm series ?ot swap- pable?power supplies deliver remarkable economy and reliability in applications that require redundancy over extended temperature ranges. these high-density, single-output supplies are available with a front panel and handle for use in sub-system racks or without handles for embedded applications. power factor correction, or-ing diodes, and current sharing make the tcm series an ideal choice for communica- tions and data processing systems utilizing distributed power or redundant power architecture. standard tcm series TCM-1000 featuring: diode isolated output for hot swap ?ero wire?slope program current sharing high power density 6.5 watt/cu. in. industry standard din connector 0.99 typical power factor dc power good and ac power fail signals true remote inhibit monotonic turn-on and turn-off extended temperature operation high efficiency 87% typical (48 v units) operating temperature range -20? to +60? TCM-1000-24 24v @ 41.6a 1000 TCM-1000-28 28v @ 35.7a 1000 TCM-1000-48 48v @ 20.8a 1000 see trs (rack system)
specifications: all models input ac input: 180-264 vac, 47-63 hz internally fused 10 a. power factor: 0.99 typical at full load. meets en61000-3.2. inrush: limited by thermistor, 40 ampere maximum (8ms), cold start. hold up time: 20 ms minimum after removal of power supply at full load. efficiency: 87% typical @ full load. ac power fail: provides ttl "o" 5 ms before output voltage goes out of regulation band upon loss of ac power. output adjustability: user adjustable ?% minimum. output: 48 v @ 20.8 amp. (1000 w max.). line regulation: ?.2% load regulation: ?% (slope program) from 0 to 100% load changes. turn on delay: 1 second typical. ripple & noise: 0.5% p-p, measured at 20 mhz bandwidth. temperature coefficient: 0.02% per degree c. stability: 0.1% over 8 hours, under constant line, load and ambient. transient response: output voltage returns to within 1% in less than 500 ? for a 50% load change. peak transient does not exceed 3%. overload protection: electronic current limit, 120% maximum. overvoltage protection: protects load against power supply induced overvoltage. trip point is factory set so that output voltage cannot exceed 136% of nominal. requires ac input to be cycled to reset. remote inhibit: contact closure or ttl "0" turns off output. dc power good: provides a ttl "0" open collector when output is above 90% of nominal maximum pull-up voltage 30 vdc; maximum sink current, 10 ma. redundancy: built-in or-ing diode, slope program current sharing, and din blade connector provide "hot swap" and "n+1" capabilities. current sharing remains within 10% of the unit's full output rating given 0.2% initial accuracy in the output voltage setting. current sharing: as calibrated at factory, modules will share current within 10% of full rated load. reverse voltage: protected against reverse voltage up to twice output voltage rating. (internal or-ing diode.) 1000 watts 13.27? 4.87? 2.49 TCM-1000 function location notes connector output z12 d14 z16 d18 (+) polarity voltage z4 d6 z8 d10 (-) polarity function location notes connector dc power good z20 reference to ac power fail d22 common inhibit z24 location 230 vac connector z32 line 1 d30 line 2 z28 safety ground ac input (180-264 vac continuous range) dc output eurocard connector - male din 41 612 level 1- type h eurocard connector - male din 41 612 level 1- type h eurocard connector - male din 41 612 level 1- type h status and control TCM-1000 5.2 lbs - 2.6 kgs dimensions: inches millimeters environmental thermal protection: shuts down power supply if overheated. automatic recovery. temperature range: -20 to +60 c, full power, de-rate to 66% maximum power @ 71 c. safety agencies: approved to ul1950; csa 22.2 #950; iec 950 and tuv en60950, class 1 selv, ce 73/23/eec//93/68/eec (low voltage directive). conducted rfi: meets fcc part 15, subpart j, class a; en55022 class b; and cispr 22 class b. output isolation: isolated from ground 100 vdc. cooling: self-cooled by internal ball-bearing fan. options option "r" - rack mount panel: special panel that is required for rack mounting. consult factory for other available options. condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com


▲Up To Search▲   

 
Price & Availability of TCM-1000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X